This website uses cookies primarily for visitor analytics. Certain pages will ask you to fill in contact details to receive additional information. On these pages you have the option of having the site log your details for future visits. Indicating you want the site to remember your details will place a cookie on your device. To view our full cookie policy, please click here. You can also view it at any time by going to our Contact Us page.

BROWSE PRODUCTS
 

Eaton Smart Distribution Boards

Eaton has introduced a range of Type B, 200A final distribution boards with integral smart metering for power and lighting. This enables specifiers and installers to meet the energy metering requirements of the current Building Regulations Part L2 cost-effectively without having to install separate distribution boards and feeders for each type of load.

The sub-metering requirements of Part L2, apply to all new and refurbished non-domestic buildings greater than 500m2 and call for energy sub-metering so that at least 90% of the estimated annual energy consumption can be assigned to specific end-use categories such as lighting, heating, pumps and fans. Traditionally, final distribution boards supply both lighting and small power loads.

Eaton’s new smart, split-metered distribution boards are suitable for three-phase or single-phase applications as standard and provide for separate measurement of lighting and small power grouped loads. Installation of the boards is simple; the metering and 200A switch disconnector incomer are completely pre-installed at the factory, allowing the installer to focus on outgoing circuit requirements. The distribution boards are offered in four sizes from 10 to 24 TPN ways. Meters are multi-function, MID-compliant instruments incorporating either pulsed output or RS485 connectivity where required.

The unique feature of this solution is the smart ‘summing’ meter which calculates and displays net values of electrical parameters for each section of the board plus total load, without the need for further external calculations. Having this net information available directly from the meter simplifies integration with any energy surveillance system.

The design utilises orthodox high-integrity shrouded busbars with embedded transducers. A single 15kA fault rated main busbar offers greater assurance of integrity compared with partially soft-cabled solutions. The embedded transducers deliver a significant reduction in board size, compared with standard current transformer based solutions, making these power and lighting boards the most compact metered solutions available.

‘High integrity earths’ for ring circuits and ‘functional clean earths are now commonplace requirements, so earthing is an important consideration. The new boards incorporate additional high integrity earths as standard; they have four earth bars. An accessory kit is supplied with each board facilitating a variety of earthing options and a single phasing option.

Removable side gland plates offer a choice of cabling options.